某电厂水塔环基施工方案

3.0 2024-11-18 0 0 238KB 35 页 3.3金币
侵权投诉
目录
1. 工程概况........................................................1
2. 施工应具备的条件................................................2
3. 施工主要机具及材料..............................................2
4. 施工方法、步骤及工期要求........................................3
5. 施工应达的质量标准及工艺要求....................................7
6. 安全及文明施工要求.............................................10
7. 成品保护措施...................................................12
8. 应提供的质量记录...............................................12
9. 编制依据.......................................................13
附件..............................................................14
一、概述..........................................................14
RJ-3...........................................................14
二、砼的水化热绝热温升值计算......................................15
三、各龄期砼中心温度..............................................15
四、砼收缩变形值计算..............................................16
五、砼收缩量温差计算..............................................16
六、收缩当量温差..................................................17
七、综合降温差由中心降温差与收缩当量温差组成......................17
八、砼的弹性模量的计算............................................18
九、混凝土的温度收缩应力计算......................................18
十、保温材料厚度计算..............................................20
1. 工程概况
******厂二期工#3冷却塔位于主厂房北侧,为双曲线型自然通风
A=5953.60 B=2807.30 ±0.000m
1065.500m,淋水面积 6500m2,塔高 125m,进风口高度 8.0m,通风筒为
现浇钢筋砼结构,壳体最大半径 46.820m,喉部半径 26.280m,最大厚度
750mm厚度 180mm8.870m 11.680m
腿,塔顶设一刚性环。
环形基础结构形式为超长环板型大体积钢筋砼结构。环基宽 5.0m,高
2.0m,中50.712m控制,环沿平向Φ16
200 温度筋;池壁设置 19 道伸缩缝,间距约 15m,伸缩缝处止水采用橡
45°17
降观测点。基底标高-4.10m,砼强度等级 C25F200P6